Plexus reinforcement connection systems are type certified and fulfil the requirements set out in the leaflet “Bending of concrete steel and requirements of casings” published by the DBV (Deutscher Beton-Verein E.V.) in the wording of January 2011. Pull out lengths are deduced in accordance with DIN 1045-1:2008-08, section. 12.3.2.

  • The surface coating of the casing has been classified as ‘smooth’ in accordance with the IBAC (Institut für Baufor. Aachen)
  • Diameter of bending roller: 6ds as per Standard
  • Bent section of metal connectors within casing
  • Transverse hooks on individual strips to simplify insertion of reinforcement
  • Galvanised casing can remain inside concrete
  • Face sides sealed with wood, thereby extremely stable
  • Plastic cover (from stirrup width 18cm with steel cover) for lower weight, easier and reduced risk of injury
  • No plastic residue remains in the concrete
3331
Bendable structural steel BST550 with Austrian and BST500 with German approval
Bond length lü: acc. to DIN 1045: acc. to ÖNORM B4200:
Ø 8mm: 32cm 29cm
Ø 10mm: 39cm 36cm
Ø 12mm: 46cm 42cm
Length of element: 1250mm
Stirrup hight: for Ø 8 and 10mm = 150mm, for Ø 12mm = 170mm
Box hight: for Ø 8mm = 30mm, for Ø 10 and 12mm = 36mm
The dimension “h” and “lü” may deviate by 1 – 2cm due to production and installation conditions.

Number of hooks in standard element

 

Stirrup distance “s” 100mm

 

Stirrup distance “s” 150mm

 

Stirrup distance “s” 200mm

 

Stirrup distance “s” 250mm

100
Processing

Process